FF109X
2 Hour UL Fire Rated Recessed Light Cover
for use with IC-rated recessed incandescent, fluorescent or LED light fixtures.
UL Fire Tested AND APPROVED
Key Benefits:
- UL Rated for 120-minute fire protection.
- UL tested and approved for use with IC-rated recessed incandescent, fluorescent or LED light fixtures.
- For Joist Spacing up to 24″ on center.
- Suitable for 2″x10″, 2″x12″, 2″x14″ and 2″x16″.
- Can be used in floor/ceiling, as well as roof/ceiling assemblies (attic). Ideal for 2 hour fire rated ceiling assemblies.
- Tested to maintain UL fire ratings of two hours or less in all UL L500, D500, G500, D200, G200, J200 and L200 series fire-rated floor/ceiling assemblies.
- UL Fire Tested to maintain fire ratings of one hour or less for all UL P200 and P500 series fire-rated roof/ceiling assemblies.
- Significant Labor savings.
- Lightweight (approx. 2.5 lbs).
- Flexible material enables cover to be fitted around obstructions. Helping to maintain UL fire rating.
- Enhances the acoustic protection of the ceiling.
- Reduces heat loss through the fixture.
- Maintenance free for fire-resitant rated ceilings.
FF109X Product Details
The FF109X is a two hour UL fire-rated, tested and approved fire barrier that can be used with a wide range of recessed lights to effectively prevent the spread of flames through a ceiling opening. Once a hole is made in the drywall to install recessed lights or speakers, the integrity of the construction and its ability to perform in a fire is reduced significantly, creating a potential fire hazard.
This is the reason why the International Building Code states:
Where floor/ceiling assemblies are required to have a 1 or 2-hour fire resistance rating, recessed fixtures shall be installed such that the required fire resistance of the ceiling will not be reduced”
The FF109X is an approved 2-hour fire rated ceiling enclosure for every major ceiling assembly including gypsum, sheetrock, drywall, acoustical tiles and suspended ceilings with any joist spacing up to 24 inches on center. The enclosure is made out of an intumescent material which will be activated in case of a fire, stopping both, flame spread and heat transmission for two hours.
Tenmat 2 Hour Fire Rated Light Covers are UL tested and approved for use with IC-rated recessed incandescent, fluorescent, LED light fixtures.TENMAT Fire Rated Light Covers can be used with most light manufacturer’s models and are suitable for new construction as well as remodel projects.
In addition to its UL 2-hour fire rated ceiling assembly and 1-hour fire rated ceiling assemblies, the FF109X also exhibits excellent thermal and acoustical insulating properties to save energy and reduce noise. The flexible and lightweight nature of the covers makes installation quick and easy, reduces the stress put on the ceiling and significantly reduces labor costs compared to standard dry-walled box constructions.